In addition to the superior performance and advanced manufacturing process of TERPS technology, GE Digital Pressure Sensor RPS/DPS8000 series can provide users with various pressure interfaces and electrical connections. The specific application needs to choose. The RPS8000 series sensor, which perfectly combines TERPS's advanced technology with high quality, high reliability and high selection flexibility, provides a unique solution for high-precision, high-stability pressure measurement. RPS is the frequency output of Fang Xingbo, DPS is RS232 or RS485 digital output, the specific parameters can be downloaded 8000 series data for details.
GE Digital Pressure Sensors RPS/DPS8000 Series Features: • High Accuracy, ±0.01%FS Over Full Compensation Temperature Range • High Stability, ±100ppm FS/year • Wide Temperature Range, -40°C to 85°C
• Optional dielectric isolation structure, especially for harsh environments • Multiple output signal options, RS232 or RS485 or frequency (TTL) output • Multiple pressure ports and electrical connections optional
GE Digital Pressure Sensors RPS/DPS8000 Series Pressure Range: 0-2 bar (0-30 psi) Absolute Pressure • 0-7 bar (0-100 psi) Absolute Pressure • 0-14 bar (0-200 psi) Absolute • 0-20 bar (0 -300psi) Absolute pressure
• 0-35 bar (0-500 psi) absolute pressure • 0-70 bar (0-1000 psi) absolute pressure (appropriate psi value is approximate); atmospheric pressure range is available with RPS/DPS 8100 series. The maximum overpressure 1.5×FS, the maximum breaking pressure 2.0×FS, the maximum withstand pressure of the housing, 7bar and the following range: 70bar • 70bar and the following range: 200bar
GE Digital Pressure Sensors RPS/DPS8000 Series Performance Specifications: There are two levels of performance indicators available: standard and enhanced.
The following accuracy specifications include the combined effects of nonlinearity, hysteresis, and repeatability, as well as temperature effects over the full compensation temperature range.
Selection Code Accuracy Accuracy (GE Digital Pressure Sensor RPS/DPS8000 Series)
A1-standard grade Accuracy: 0.02% FS Accuracy: 0.0225% FS
A2-level improvement Accuracy: 0.01%FS Accuracy: 0.0144%FS
For the frequency output mode, the above accuracy can be calculated based on the polynomial curve fitting algorithm provided with the sensor and the corresponding coefficients.
Compensation temperature range: Two compensation temperature ranges are available: -10°C - 50°C and -40°C - 85°C, temperature effect: All temperature effects are included in the accuracy specification, long-term stability: Standard level: ±0.02% FS/year, step: ±0.01% FS/year Note: Unless otherwise specified, the above specifications are obtained under reference conditions: 25°C ± 5°C